Contents
Download PDF
pdf Download XML
20425 Views
11097 Downloads
Share this article
Review Article | Volume 26 Issue 1 (, 2021) | Pages 90 - 97
Aortic Valve Replacement with the Labcor TLPB Supra™ Porcine Bioprosthesis: Intermediate Clinical and Echocardiographic Outcomes
 ,
 ,
 ,
 ,
 ,
 ,
 ,
 ,
1
Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bürkle-de-la-Camp Platz. 1, 44789 Bochum, Germany. Electronic correspondence: markus.schloemicher@bergmannsheil.de.
2
Department of Cardiothoracic Surgery, Ruhr-University Hospital Bergmannsheil, Bürkle-de-la-Camp Platz. 1, 44789 Bochum, Germany.
Under a Creative Commons license
PMID : -28544836
Published
Jan. 10, 2017
Abstract

Background: The Labcor TBLP Supra™ prosthesis is a second-generation tissue valve that has evolved from the Labcor TBLP™ prosthesis, first introduced in 1984. The Supra prosthesis is a triple-composite porcine valve, with no specific anticalcification treatment being used in its production other than standard tissue fixation with 0.4% glutaraldehyde. To date, more than 100,000 Supra valves have been implanted, mainly in South America. Despite this remarkably high number of implants, only marginal data exist concerning durability and safety issues. Hence, the study aim was to analyze short-term and intermediate outcomes relating to the clinical and hemodynamic performance of the Supra valve, as well as complication rates METHODS: A follow up study was initiated to evaluate outcomes and durability of the Labcor Supra prosthesis. Between September 2004 and October 2010, a total of 331 patients (mean age 75.8 ± 7.2 years; mean logistic EuroSCORE 8.5 ± 2.3%) underwent aortic valve replacement using the Supra porcine bioprosthesis.

Results: The 30-day mortality rate was 4.8% (n = 16). The overall actuarial five-year survival was 72.3 ± 4.9%, and eight-year survival was 60.4 ± 5.6%. Actuarial freedom from reoperation was 96.3 ± 2.4% after five years, and 92.5 ± 3.5% after eight years. Actuarial freedom from structural valve deterioration (SVD) was 99.7 ± 0.3% at five years, and 97.2 ± 0.8% at eight years; actuarial freedom from thromboembolism was 97.5 ± 1.0% and 95.7 ± 1.6% at these times. Actuarial freedom from event rates for endocarditis were 99.5 ± 0.3% and 96.8 ± 0.6%, and 96.1 ± 0.9% and 93.0 ± 1.4% for reoperation CONCLUSIONS: No evidence was found of increased rates of SVD. All parameters studied were comparable to those examined for other second-generation porcine prostheses. Further long-term follow up investigations are required however, for the final judgment of this prosthesis.

 

 

 

How to cite: 

Keywords
Recommended Articles
Research Article
Association of Vitamin D Deficiency with Autoimmune Thyroid Disorders
Published: 07/11/2025
Download PDF
Read Article
Research Article
To determine the prevalence and assess the effect of allergic rhinitis in school-aged children
Published: 09/05/2014
Download PDF
Read Article
Research Article
A study to correlate the incidence of sensorineural hearing loss in type of chronic otitis media
Published: 19/02/2015
Download PDF
Read Article
Research Article
Echocardiographic Parameters in Acute Coronary Syndrome Individuals Suffering from Chronic Obstructive Pulmonary Diseases
...
Published: 07/11/2025
Download PDF
Read Article
© Copyright Journal of Heart Valve Disease