Contents
Download PDF
pdf Download XML
236509 Views
10952 Downloads
Share this article
Research Article | Volume 27 Issue 1 (, 2022) | Pages 65 - 70
Relationship Between Pulmonary Venous Flow and Prosthetic Mitral Valve Thrombosis
 ,
 ,
 ,
 ,
 ,
 ,
 ,
1
Kartal Koşuyolu Heart Training and Research Hospital, Department of Cardiology, İstanbul, Turkey. Electronic correspondence: sinancersit@hotmail.com.
2
Kartal Koşuyolu Heart Training and Research Hospital, Department of Cardiology, İstanbul, Turkey.
Under a Creative Commons license
PMID : -30560601
Published
Jan. 9, 2018
Abstract

Background: Prosthetic valve thrombosis (PVT) may impair pulmonary venous flow (PVF) and left atrial appendage (LAA) functions. An investigation was conducted to determine the association between left superior PVF and LAA functions and mitral PVT.

Methods: This observational case-control study included 100 consecutive patients (87 females, 13 males; mean age 59 years; range 35-71 years) with mechanical mitral PVT, and 50 age- and gender-matched otherwise healthy controls with normally functioning mitral prostheses. All patients were included after comprehensive transesophageal echocardiography (TEE) examinations for the presence and quantification of PVT, the left atrial diameter, and LAA length. Peak systolic velocity (PSV), velocity-time integral of systolic flow (VTI-s), peak diastolic velocity (PDV), velocity-time integral of diastolic flow (VTI-d), systolic fraction (SFr) of the left upper PVF and the flow of the LAA orifice were each recorded using color-guided pulsed-wave Doppler imaging during TEE.

Results: The PSV [30 cm/s (range: 13-77 cm/s) versus 44 cm/s (range: 16-71 cm/s)], respectively (p = 0.002), VTI-s [(2.85 cm (range: 0.5-10.7 cm) versus 5 cm (range: 1.3-12.7 cm)], respectively (p <0.001), VTI-d [(3 cm (range: 0.6-9.7 cm) versus 4.2 cm (range: 1.5-8.3 cm)], respectively (p <0.001), SFr (45.5% (range: 15.66-67.44%) versus 50 % (range: 21.11-82.61%)], respectively (p = 0.008), and LAA orifice velocity [(23 cm/s (range: 11-75 cm/s) versus 34 cm/s (range: 10-112 cm/s)], respectively (p = 0.011) were each significantly lower in patients with PVT compared to controls. The PDV was similar between groups. Patients with obstructive PVT (n = 21) had a lower PDV and a higher VTI-d compared to those with non-obstructive PVT.

Conclusions: Mitral mechanical PVT is associated with decreased systolic PVF and LAA function. The presence of obstructive PVT is associated with further limitations of diastolic flow velocity, and a compensatory prolongation of diastolic flow of the left upper pulmonary vein.

 

 

 

How to cite: Cerşit, S., Gündüz, S., Ozan Gürsoy, M., Karakoyun, S., Kalçık, M., Bayam, E., Yesin, M., & Özkan, M. (2018). Relationship Between Pulmonary Venous Flow and Prosthetic Mitral Valve Thrombosis. The Journal of heart valve disease27(1), 65–70.

 
Keywords
Recommended Articles
Research Article
A Prospective Hospital-Based Cross-Sectional Observational Study on Sonographic Assessment of Fetal Kidney Length as a Predictor of Gestational Age in the Second and Third Trimester at a Tertiary Care Centre in Indore
...
Published: 28/10/2025
Download PDF
Read Article
Research Article
To study Cholecystectomy in esource limited settings
...
Published: 28/10/2025
Download PDF
Read Article
Research Article
Changes in liver function tests and incidence of acute liver injury after on-pump CABG surgery
...
Published: 28/10/2025
Download PDF
Read Article
Research Article
A Study to Compare Maternal and Fetal Outcomes in Antenatal Women Undergoing Elective and Emergency Caesarean Section at A Tertiary Care Center in North West Rajasthan
...
Published: 12/10/2025
Download PDF
Read Article
© Copyright Journal of Heart Valve Disease