Contents
Download PDF
pdf Download XML
200465 Views
11583 Downloads
Share this article
Review Article | volume 7 Issue 1 (, 2001) | Pages 102 - 107
A method for estimating aortic regurgitant effective orifice area by digital Doppler color flow mapping
 ,
 ,
 ,
 ,
 ,
1
Laboratory of Animal Medicine and Surgery, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA.
Under a Creative Commons license
PMID : -9502147
Published
Jan. 13, 1998
Abstract

Background and aims of the study: Although non-invasive assessment of the severity of aortic regurgitation (AR) is important, quantitative evaluation of AR can be difficult in clinical settings. Most Doppler echocardiographic methods have been compared with angiographic grading of AR severity. However, while aortic angiography is used widely for grading AR severity, the method is only semi-quantitative. A computed semi-automatic digital color Doppler method has recently been described for calculating stroke volume and cardiac output. The study aim was to develop a method of evaluating AR severity by using a digital automated color Doppler method (ACM) along with continuous wave (CW) Doppler for estimating aortic regurgitant effective orifice area.

Methods: A total of 22 different hemodynamic conditions were studied in six sheep. Regurgitant volumes (RV) were determined by electromagnetic flowmetry (EM) and by ACM. AR effective orifice areas (EOAs) were determined by dividing each of the RVs by the time integrals of the AR continuous wave velocities. AR EOAs by ACM were compared with those obtained by EM and with other EM indices of regurgitant severity. ACM was accurate for quantifying AR EOAs (r = 0.96).

Results and conclusions: Calculated AR EOA correlated well with peak AR flow and regurgitant fraction by EM. The combined ACM/CW Doppler method can be useful for estimating non-invasively the aortic regurgitant EOA and for evaluating the severity of AR.

 

 

 

How to cite: Chikada, M., Shiota, T., Aida, S., Yamada, I., Sahn, D. J., & Jones, M. (1998). A method for estimating aortic regurgitant effective orifice area by digital Doppler color flow mapping. The Journal of heart valve disease7(1), 102–107.

 
Keywords
Recommended Articles
Research Article
To Study Smartphone Addiction and Sleep Quality among Medical Students
Published: 30/08/2025
Download PDF
Read Article
Research Article
Serum Neuroinflammatory Biomarker Profiles Across Major Neurodegenerative Diseases: A Prospective Cross-Sectional Study from a Tertiary Care Centre in India
Published: 29/12/2025
Download PDF
Read Article
Research Article
Prevalence of Anemia and Its Association with Respiratory Infections Among Pediatric Patients: A Hospital-Based Cross-Sectional Study
Published: 27/11/2015
Download PDF
Read Article
Research Article
A Clinical Study of Menstrual Patterns in Women Presenting with Ovarian Masses in a Tertiary Care Hospital
Published: 22/09/2012
Download PDF
Read Article
© Copyright Journal of Heart Valve Disease